Daikin · Split air conditioners · Daikin Sensira FTXF-E / ATXF-E (wall-mounted split, R32)

A5Freeze-up protection or high-pressure control

Name in the manufacturer's documentation (user manual): Freeze-up protection or high-pressure control[1]

In plain words (editorial)

Freeze-up protection or high-pressure control. The service manual lists blocked air flow at the indoor unit, a dirty or faulty air filter, a dirty heat exchanger, the heat exchanger thermistor or the PCB – and recommends checking in that order.

When to call a service technician: Remove objects blocking the indoor unit and clean the air filter as in the user manual; if the code returns, call a technician.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

⚠ Some information comes from unofficial sources (copies shared by users, transcriptions, forums). They are marked below. Check them against the manufacturer's documentation before working on the device.

  1. [1] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 36 official manufacturer document checked manually Freeze-up protection or high-pressure control
  2. [2] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Airflow of the indoor unit is blocked
  3. [3] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Faulty or dirty air filter
  4. [4] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Dirty indoor unit heat exchanger
  5. [5] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Faulty indoor unit heat exchanger thermistor
  6. [6] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Faulty indoor unit main PCB
  7. [7] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Check for objects near the indoor unit that may block the airflow
  8. [8] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Clean the air filter of the indoor unit
  9. [9] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Clean the indoor unit heat exchanger
  10. [10] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified Perform a check of the indoor unit heat exchanger thermistor
  11. [11] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified It is recommended to perform the checks in the listed order
  12. [12] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 8 ⚠ unofficial source quote verified contact the helpdesk