Daikin · Split air conditioners · Daikin Sensira FTXF-E / ATXF-E (wall-mounted split, R32)
E1Outdoor unit PCB abnormality
Name in the manufacturer's documentation (user manual): Outdoor unit PCB abnormality
[1]
In plain words (editorial)
The outdoor unit PCB reports an abnormality (the main PCB detects an EEPROM problem). The service manual also lists power supply disturbances, the fan motor and the compressor wiring as possible causes.
When to call a service technician: The checks listed by the service manual need the unit opened – call a service technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
- Main pcb detects that eeprom is abnormal[2]
Possible causes (source text)
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
⚠ Some information comes from unofficial sources (copies shared by users, transcriptions, forums). They are marked below. Check them against the manufacturer's documentation before working on the device.
- [1] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 37 official manufacturer document checked manually
Outdoor unit PCB abnormality
- [2] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
main pcb detects that eeprom is abnormal.
- [3] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
faulty main pcb.
- [4] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
▪ faulty or disturbance of the power supply (imbalance >4%), ▪ power drop, ▪ short circuit.
- [5] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
faulty outdoor unit fan motor.
- [6] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 11 ⚠ unofficial source quote verified
faulty compressor or miswiring of the compressor power supply cable.
- [7] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
perform a check of the main pcb.
- [8] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
check if the power supply is conform with the regulations.
- [9] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
perform a check of the outdoor unit fan motor.
- [10] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 10 ⚠ unofficial source quote verified
perform a check of the compressor.