Daikin · Split air conditioners · Daikin Sensira FTXF-E / ATXF-E (wall-mounted split, R32)

UAIndoor/outdoor unit combination fault

Name in the manufacturer's documentation (user manual): Indoor/outdoor unit combination fault[1]

In plain words (editorial)

The indoor and outdoor units are an improper combination, or the wiring between them or a PCB is faulty.

When to call a service technician: Contact your installer or Daikin dealer.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

⚠ Some information comes from unofficial sources (copies shared by users, transcriptions, forums). They are marked below. Check them against the manufacturer's documentation before working on the device.

  1. [1] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 36 official manufacturer document checked manually Indoor/outdoor unit combination fault
  2. [2] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 28 ⚠ unofficial source quote verified improper combination of outdoor and indoor unit.
  3. [3] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 28 ⚠ unofficial source quote verified faulty wiring between the outdoor unit and the indoor unit.
  4. [4] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 28 ⚠ unofficial source quote verified faulty main pcb.
  5. [5] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 28 ⚠ unofficial source quote verified faulty indoor unit main pcb.
  6. [6] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 28 ⚠ unofficial source quote verified perform a check of the power supply, connections, wiring,… between the outdoor unit and the indoor unit.
  7. [7] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 28 ⚠ unofficial source quote verified perform a check of the main pcb.
  8. [8] Daikin – Service manual Split Sensira R32 FTXF20~71A + FTXF20~25B + FTXF20~42C (+ ATXF/RXF/ARXF), ESIE18-12E – 2021.02 – text capture of pp. 2–36 from easymanua.ls (ESIE18-12E) , p. 28 ⚠ unofficial source quote verified perform a check of the indoor unit main pcb.