Daikin · Daikin Sensira FTXF-E / ATXF-E (wall-mounted split, R32) · Maintenance
Daikin Sensira: how to clean the air filters (and prepare for a long stop)
Summary (editorial)
Stop the unit and switch off the breaker first. The manual explains removing, washing and drying the filters and warns not to clean inside parts yourself.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
From the manufacturer's documentation (English source wording, with page)
- Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord[1]
- Do not use gasoline, benzene, thinner, polishing powder or liquid insecticide; do not use water or air of 40°C or higher[2]
- As an end user, you may never clean inside parts of the unit by yourself; this work must be performed by a qualified service person[3]
- Do not touch the heat exchanger fins. These fins are sharp and could result in cutting injuries[4]
- Operating the unit with dirty filters: cannot deodorise the air, cannot clean the air, poor heating/cooling, causes odour[5]
- 7.5: Hold the front panel by the panel tabs on both sides and open it[6]
- 7.6: Push the tab at the centre of each air filter, then pull it down; pull out the air filters[7]
- Wash the air filters with water or clean them with a vacuum cleaner[8]
- Soak in lukewarm water for about 10 to 15 minutes; install all filters back in their original positions[9]
- If the dust does not come off easily, wash them with a neutral detergent diluted in lukewarm water. Dry the air filters in the shade[10]
- It is recommended to clean the air filters every 2 weeks[11]
- 7.7: Gently press the front panel at both sides and at the center until it clicks[12]
- Before a long idle period: operate the unit in fan only mode for several hours to dry the inside; after operation stops, turn the breaker off; clean the air filters; remove the batteries from the remote control[13]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 29 official manufacturer document quote verified
before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord.
- [2] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 29 official manufacturer document quote verified
do not use water or air of 40°c or higher.
- [3] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 29 official manufacturer document quote verified
you may never clean inside parts of the unit by yourself;
- [4] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 29 official manufacturer document quote verified
do not touch the heat exchanger fins.
- [5] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 30 official manufacturer document quote verified
operating the unit with dirty filters means that the filter:
- [6] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 30 official manufacturer document quote verified
hold the front panel by the panel tabs on both sides and open it.
- [7] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 30 official manufacturer document quote verified
push the tab at the centre of each air filter, then pull it down.
- [8] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 30 official manufacturer document quote verified
wash the air filters with water or clean them with a vacuum cleaner.
- [9] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 31 official manufacturer document quote verified
soak in lukewarm water for about 10 to 15 minutes.
- [10] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 31 official manufacturer document quote verified
dry the air filters in the shade.
- [11] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 31 official manufacturer document quote verified
it is recommended to clean the air filters every 2 weeks.
- [12] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 31 official manufacturer document quote verified
gently press the front panel at both sides and at the center until it clicks.
- [13] Daikin – User reference guide FTXF20~42E5V1B + ATXF20~42E5V1B, 4D526466-14K (2022.09) (4DEN526466-14K) , p. 31 official manufacturer document quote verified
operate the unit in fan only mode for several hours to dry the inside of the unit.