Daikin · Heat pumps · Daikin Altherma 3 R F (split heat pump, R32)

C0-00Flow sensor malfunction

Name in the manufacturer's documentation (service manual): Flow sensor malfunction[1]

In plain words (editorial)

The water flow sensor reports a malfunction. The documentation lists low water pressure, low water flow, air in the water circuit, flow caused by an external pump, or a faulty flow sensor; the checks start with the water pressure and the flow.

When to call a service technician: If the pressure is fine, call the installer to purge the circuit and check the sensor.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Daikin Altherma 3 R F – ERGA04~08E + EHVH/X04+08S18+23E – Installer reference guide (4P629086-1D (2024.04)) , p. 254 official manufacturer document quote verified C0-00 Flow sensor malfunction
  2. [2] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified water pressure is too low.
  3. [3] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified water flow is too low.
  4. [4] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified air in the water circuit.
  5. [5] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified the detected water flow is caused by an external pump.
  6. [6] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified faulty water flow sensor.
  7. [7] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified faulty hydro pcb.
  8. [8] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified check the water pressure.
  9. [9] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified check the water flow.
  10. [10] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified purge the water circuit.
  11. [11] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified check the water circuit for an external pump.
  12. [12] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified perform an electrical check of the water flow sensor.
  13. [13] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 34 manufacturer document – copy from a distributor quote verified perform a check of the hydro pcb.