Daikin · Heat pumps · Daikin Altherma 3 R F (split heat pump, R32)
EC-00Abnormal increase tank temperature
Name in the manufacturer's documentation (service manual): Abnormal increase tank temperature
[1]
In plain words (editorial)
The tank temperature rises abnormally. The checks listed in the manual concern the refrigerant circuit, sensors and PCBs – a job for a Daikin-qualified installer.
When to call a service technician: Contact your installer or Daikin dealer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
- Faulty wiring between the remote controller and the unit[2]
- User interface (main pcb) receives no power[3]
- Faulty hydro pcb[4]
- Closed stop valve in the refrigerant circuit[5]
- Clogged refrigerant circuit[6]
- Refrigerant overcharge or shortage[7]
- Non‑condensables and/or humidity in the refrigerant circuit[8]
Steps given by the manufacturer (source text)
- Check the communication wiring between the remote controller and the unit[9]
- Perform a power check of the user interface (main pcb) on the unit[10]
- Perform a check of the hydro pcb[11]
- Check that all stop valves of the refrigerant circuit are open[12]
- Check if the refrigerant circuit is clogged[13]
- Check if the refrigerant circuit is correctly charged[14]
- Check for the presence of non‑condensables and/or humidity in the refrigerant circuit[15]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Daikin Altherma 3 R F – ERGA04~08E + EHVH/X04+08S18+23E – Installer reference guide (4P629086-1D (2024.04)) , p. 254 official manufacturer document quote verified
EC-00 Abnormal increase tank temperature
- [2] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
faulty wiring between the remote controller and the unit.
- [3] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
user interface (main pcb) receives no power.
- [4] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
faulty hydro pcb.
- [5] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
closed stop valve in the refrigerant circuit.
- [6] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
clogged refrigerant circuit.
- [7] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
refrigerant overcharge or shortage.
- [8] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
non‑condensables and/or humidity in the refrigerant circuit.
- [9] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
check the communication wiring between the remote controller and the unit.
- [10] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
perform a power check of the user interface (main pcb) on the unit.
- [11] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
perform a check of the hydro pcb.
- [12] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
check that all stop valves of the refrigerant circuit are open.
- [13] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
check if the refrigerant circuit is clogged.
- [14] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
check if the refrigerant circuit is correctly charged.
- [15] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 43 manufacturer document – copy from a distributor quote verified
check for the presence of non‑condensables and/or humidity in the refrigerant circuit.