H6-00OU: Malfunction of position detection sensor

Name in the manufacturer's documentation (service manual): OU: Malfunction of position detection sensor[1]

This page only quotes the original English documentation. A plain-language explanation has not been written yet, so the page is not indexed by search engines.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Daikin Altherma 3 R F – ERGA04~08E + EHVH/X04+08S18+23E – Installer reference guide (4P629086-1D (2024.04)) , p. 255 official manufacturer document quote verified H6-00 OU: Malfunction of position detection sensor
  2. [2] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified faulty compressor or miswiring of the compressor power supply cable.
  3. [3] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified faulty main pcb.
  4. [4] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified faulty inverter pcb.
  5. [5] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified closed stop valve in the refrigerant circuit.
  6. [6] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified clogged refrigerant circuit.
  7. [7] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified refrigerant overcharge or shortage.
  8. [8] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified non‑condensables and/or humidity in the refrigerant circuit.
  9. [9] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified ▪ faulty or disturbance of the power supply (power supply must be within range of nominal operating voltage ±4%), ▪ power drop, ▪ short circuit.
  10. [10] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified perform a check of the compressor.
  11. [11] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified perform a check of the main pcb.
  12. [12] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified perform a check of the inverter pcb.
  13. [13] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified check that all stop valves of the refrigerant circuit are open.
  14. [14] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified check if the refrigerant circuit is clogged.
  15. [15] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified check if the refrigerant circuit is correctly charged.
  16. [16] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified check for the presence of non‑condensables and/or humidity in the refrigerant circuit.
  17. [17] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 49 manufacturer document – copy from a distributor quote verified check if the power supply is compliant with the regulations.