Daikin · Heat pumps · Daikin Altherma 3 R F (split heat pump, R32)

U0-00OU: Shortage of refrigerant

Name in the manufacturer's documentation (service manual): OU: Shortage of refrigerant[1]

In plain words (editorial)

The outdoor unit suspects a shortage of refrigerant. The documentation also lists faulty refrigerant thermistors or pressure sensor, a closed stop valve and a clogged circuit – so it is not always a leak.

When to call a service technician: Call a service technician with F-gas certification.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Daikin Altherma 3 R F – ERGA04~08E + EHVH/X04+08S18+23E – Installer reference guide (4P629086-1D (2024.04)) , p. 255 official manufacturer document quote verified U0-00 OU: Shortage of refrigerant
  2. [2] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified faulty refrigerant side thermistor(s).
  3. [3] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified faulty refrigerant pressure sensor.
  4. [4] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified closed stop valve in the refrigerant circuit.
  5. [5] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified clogged refrigerant circuit.
  6. [6] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified refrigerant shortage.
  7. [7] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified non‑condensables and/or humidity in the refrigerant circuit.
  8. [8] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified faulty compressor or miswiring of the compressor power supply cable.
  9. [9] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified faulty inverter pcb.
  10. [10] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified faulty main pcb.
  11. [11] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified perform a check of all refrigerant side thermistors.
  12. [12] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified perform a check of the refrigerant pressure sensor.
  13. [13] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified check that all stop valves of the refrigerant circuit are open.
  14. [14] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified check if the refrigerant circuit is clogged.
  15. [15] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified check if the refrigerant circuit is correctly charged.
  16. [16] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified check for the presence of non‑condensables and/or humidity in the refrigerant circuit.
  17. [17] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified perform a check of the compressor.
  18. [18] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified perform a check of the inverter pcb.
  19. [19] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 58 manufacturer document – copy from a distributor quote verified perform a check of the main pcb.