GoodWe · GoodWe ET G2 6–15 kW (three-phase hybrid inverter) · Operation
What the GoodWe ET G2 indicators mean (power, BACK-UP, communication)
Summary (editorial)
The indicators show power, self-check, grid operation, back-up output and communication states, as described in the manual.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
From the manufacturer's documentation (English source wording, with page)
- Power indicator yellow solid: the inverter is powered on and in standby mode (colour from page image)[1]
- Power indicator green blinking: the inverter is starting and in self-check mode (from page image)[2]
- Power indicator green solid: the inverter is operating normally in grid-connected power generation or off-grid mode (from page image)[3]
- Power indicator red blinking: BACK-UP output Overload (from page image)[4]
- Power indicator red solid: System Fault (from page image)[5]
- Power indicator off: the inverter is powered off[6]
- BACK-UP indicator yellow solid: grid abnormal, and the inverter BACK-UP port is supplying power normally (from page image)[7]
- BACK-UP indicator green solid: grid normal, and the BACK-UP port is supplying power normally; off: no power supply at the BACK-UP port (from page image)[8]
- Communication indicator yellow solid: the inverter has not established a connection with the communication terminal (from page image)[9]
- Communication indicator green blinking: communication fault between the communication terminal and the cloud server (from page image)[10]
- Communication indicator green solid: inverter monitoring is normal; off: the inverter monitoring module is not started (from page image)[11]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
the inverter is powered on and in standby mode.
- [2] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
the inverter is starting and in self-check mode.
- [3] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
the inverter is operating normally in grid
- [4] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
back-up output overload.
- [5] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
system fault.
- [6] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
the inverter is powered off.
- [7] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
grid abnormal, and the inverter back-up port is
- [8] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 168 official manufacturer document quote verified
no power supply at the back-up port.
- [9] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 169 official manufacturer document quote verified
the inverter has not established a connection
- [10] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 169 official manufacturer document quote verified
communication fault between the
- [11] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 169 official manufacturer document quote verified
inverter monitoring is normal.