GoodWe · GoodWe ET G2 6–15 kW (three-phase hybrid inverter) · Procedure
GoodWe ET G2: switching the system (inverter + battery) off and on in a safe order
Summary (editorial)
De-energise the system before any work and wait the time on the label. The manual gives the power-off order and how to restart the battery.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
From the manufacturer's documentation (English source wording, with page)
- When performing operation and maintenance on equipment in the system, de-energize the system. Operating equipment while live may cause equipment damage or electric shock hazards[1]
- After the equipment is powered off, internal components take a certain amount of time to discharge. Wait according to the time specified on the label until the equipment is completely discharged[2]
- When there are multiple batteries in the system, powering off any one battery will power off all batteries[3]
- To restart the battery, use the air switch to power it on[4]
- Figure 80 System Power-Off (read from the page image): Power Off order 3 (BACK-UP load breaker) → 1 → 2 (ON-GRID breakers) → 4 (battery breaker, optional) → 5 (battery system breaker/switch) → 6 (DC switch); Power On order 4 → 5 → 6 → 1 → 2 → 3[5]
- 4: Optional according to local laws and regulations[6]
- System cleaning: check the heat sink, fan, and air inlet/outlet for foreign objects and dust; check whether debris has accumulated around the equipment – once every six months[7]
- If the internal copper wire of the conductive wire is exposed, do not touch it. High voltage hazard. Please contact after-sales service personnel[8]
- If any problem that may affect the battery or energy storage inverter system is found, please contact after-sales personnel. Unauthorized disassembly is prohibited[9]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 182 official manufacturer document quote verified
when performing operation and maintenance on equipment in the system, de- energize the system.
- [2] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 182 official manufacturer document quote verified
wait according to the time specified on the label until the equipment is completely discharged.
- [3] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 182 official manufacturer document quote verified
when there are multiple batteries in the system, powering off any one battery will power off all batteries.
- [4] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 182 official manufacturer document quote verified
to restart the battery, use the air switch to power it on.
- [5] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 183 official manufacturer document quote verified
figure80 system power-off
- [6] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 183 official manufacturer document quote verified
optional according to local laws and regulations.
- [7] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 185 official manufacturer document quote verified
check the heat sink, fan, and air inlet/outlet for foreign objects and dust.
- [8] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 185 official manufacturer document quote verified
if the internal copper wire of the conductive wire is exposed, do not touch it. high voltage hazard.
- [9] GoodWe Residential Smart Inverter Solutions – ET G2 6-15K (+ LX F / LX D) – User Manual V2.2 (2026-09-30) (V2.2-2026-09-30) , p. 185 official manufacturer document quote verified
unauthorized disassembly is prohibited.