GoodWe · GoodWe ET 5–10 kW (three-phase hybrid inverter) · Procedure
How to read an error and safely restart a GoodWe ET inverter
Summary (editorial)
The error is shown in the app or on the indicators. The manual describes the safe order for switching the system off and on.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
From the manufacturer's documentation (English source wording, with page)
- Error messages displayed on PV Master App or reported by e-mail[1]
- FAULT LED ON = fault has occurred[2]
- To shut down during an event turn off the inverter DC switch and the battery DC breaker[3]
- After rectification turn on the inverter DC switch and the battery DC breaker[4]
- Before electrical work disconnect DC and AC for at least 5 minutes[5]
- Inverter surface can exceed 60 °C[6]
- Utility Loss: turn off AC breaker and turn on again in 5 mins[7]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] GoodWe Hybrid Inverter ET Series | ET Plus Series – User Manual V1.1 (2021-02-10) (V1.1-2021-02-10) , p. 35 official manufacturer document quote verified
will be displayed on PV Master App or reported by e-mail
- [2] GoodWe Hybrid Inverter ET Series | ET Plus Series – User Manual V1.1 (2021-02-10) (V1.1-2021-02-10) , p. 8 official manufacturer document quote verified
ON = Fault has occurred
- [3] GoodWe Hybrid Inverter ET Series | ET Plus Series – User Manual V1.1 (2021-02-10) (V1.1-2021-02-10) , p. 34 official manufacturer document quote verified
you shall turn off the inverter DC switch and the battery DC breaker
- [4] GoodWe Hybrid Inverter ET Series | ET Plus Series – User Manual V1.1 (2021-02-10) (V1.1-2021-02-10) , p. 34 official manufacturer document quote verified
you shall turn on the inverter DC switch and the battery DC breaker
- [5] GoodWe Hybrid Inverter ET Series | ET Plus Series – User Manual V1.1 (2021-02-10) (V1.1-2021-02-10) , p. 6 official manufacturer document quote verified
for at least 5 minutes to make sure
- [6] GoodWe Hybrid Inverter ET Series | ET Plus Series – User Manual V1.1 (2021-02-10) (V1.1-2021-02-10) , p. 6 official manufacturer document quote verified
The temperature of the inverter surface can exceed 60℃ during operation
- [7] GoodWe Hybrid Inverter ET Series | ET Plus Series – User Manual V1.1 (2021-02-10) (V1.1-2021-02-10) , p. 35 official manufacturer document quote verified
please try to turn off AC breaker and turn on again in 5 mins