Growatt · PV inverters · Growatt MIN TL-XE / TL-X (single-phase grid inverter, 2.5–6 kW)
Error: 203PV Isolation Low
Name in the manufacturer's documentation (user manual): PV Isolation Low
[1]
In plain words (editorial)
The insulation of the PV side is too low – current may leak to earth. The manual lists checks of the panel enclosure and inverter grounding, whether the DC breaker got wet, and the impedance of PV+ and PV− to ground.
When to call a service technician: These checks are for the installer; if the error persists, contact Growatt.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
- Insulation problem[2]
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Installation & Operation Manual – MIN 2500–6000TL-XE/X (044.0098100, ed. 2022-05) (044.0098100) , p. 23 official manufacturer document quote verified
PV Isolation Low Error: 203
- [2] Installation & Operation Manual – MIN 2500–6000TL-XE/X (044.0098100, ed. 2022-05) (044.0098100) , p. 23 official manufacturer document quote verified
Insulation problem
- [3] Installation & Operation Manual – MIN 2500–6000TL-XE/X (044.0098100, ed. 2022-05) (044.0098100) , p. 23 official manufacturer document quote verified
Check if panel enclosure ground properly.
- [4] Installation & Operation Manual – MIN 2500–6000TL-XE/X (044.0098100, ed. 2022-05) (044.0098100) , p. 23 official manufacturer document quote verified
Check if inverter ground properly.
- [5] Installation & Operation Manual – MIN 2500–6000TL-XE/X (044.0098100, ed. 2022-05) (044.0098100) , p. 23 official manufacturer document quote verified
Check if the DC breaker gets wet.
- [6] Installation & Operation Manual – MIN 2500–6000TL-XE/X (044.0098100, ed. 2022-05) (044.0098100) , p. 23 official manufacturer document quote verified
between ground (must be more than 25