Haier · Haier Flexis Plus (wall-mounted split, R32) · Troubleshooting
Haier Flexis Plus: fan stopped, no warm air – what is normal operation
Summary (editorial)
The manual describes situations where the indoor fan stops or runs slowly on purpose (cold air prevention, residual heat, restart delay).
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
From the manufacturer's documentation (English source wording, with page)
- Defrosting: when the system receives the defrosting signal from outdoors, the indoor fan will stop and the indoor temperature display won't change; any indoor coil malfunctions will be neglected until the compressor has been started up for 30 seconds after defrosting[1]
- After outdoor defrosting finishes, the system operates at the cold air proof mode[2]
- Cold air proof operation: in heating the indoor fan speed depends on coil temperature; the indoor fan will stop when the coil temperature is below the THhot0[3]
- Residue heat sending: the indoor fan will send the residue heat at a low speed for 20 seconds[4]
- Auto restart: automatic return to previous operation conditions after sudden power blackout[5]
- The compressor will be restarted again (the requirement of 3 minutes' delay should be satisfied)[6]
- Automatic indoor fan: when room temperature approaches the set temperature, speed changes from high to medium to low[7]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Haier – Service Manual, Model AS35S2SF1FA-BH (Flexis Plus), Version V1, 2020-11-14 (V1 (2020-11-14)) , p. 17 official manufacturer document quote verified
the indoor fan will stop and the indoor temperature display won't change.
- [2] Haier – Service Manual, Model AS35S2SF1FA-BH (Flexis Plus), Version V1, 2020-11-14 (V1 (2020-11-14)) , p. 17 official manufacturer document quote verified
the system operates at the cold air proof mode.
- [3] Haier – Service Manual, Model AS35S2SF1FA-BH (Flexis Plus), Version V1, 2020-11-14 (V1 (2020-11-14)) , p. 17 official manufacturer document quote verified
the indoor fan will stop when the coil temperature is below the thhot0.
- [4] Haier – Service Manual, Model AS35S2SF1FA-BH (Flexis Plus), Version V1, 2020-11-14 (V1 (2020-11-14)) , p. 17 official manufacturer document quote verified
the indoor fan will send the residue heat at a low speed for 20 seconds.
- [5] Haier – Service Manual, Model AS35S2SF1FA-BH (Flexis Plus), Version V1, 2020-11-14 (V1 (2020-11-14)) , p. 9 official manufacturer document quote verified
automatic return to previous operation conditions after sudden power blackout
- [6] Haier – Service Manual, Model AS35S2SF1FA-BH (Flexis Plus), Version V1, 2020-11-14 (V1 (2020-11-14)) , p. 15 official manufacturer document quote verified
the requirement of 3 minutes' delay should be satisfied.
- [7] Haier – Service Manual, Model AS35S2SF1FA-BH (Flexis Plus), Version V1, 2020-11-14 (V1 (2020-11-14)) , p. 17 official manufacturer document quote verified
when ts≤tr≤ts+2℃, medium speed.