Alarm 2035Grid Voltage Imbalance

Name in the manufacturer's documentation (fault list): Grid Voltage Imbalance[1]

In plain words (editorial)

The three grid phases differ greatly in voltage; the inverter shuts down. If it happens only occasionally, the grid was temporarily abnormal and the inverter recovers automatically once the grid is normal again.

When to call a service technician: If it happens frequently or persists, have your installer check the AC cable connection and, if needed, contact the local power operator.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 42 official manufacturer document quote verified 2035 Grid Voltage Imbalance
  2. [2] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 42 official manufacturer document quote verified the three phases of the power grid differ greatly in voltage.
  3. [3] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 41 official manufacturer document quote verified if the alarm occurs occasionally, the power grid may be abnormal temporarily. the device automatically recovers after detecting that the power grid becomes normal.
  4. [4] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 42 official manufacturer document quote verified if the alarm occurs frequently, check whether the power grid voltage is within the normal range. if not, contact the local power operator.
  5. [5] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 42 official manufacturer document quote verified if the fault persists for a long time, check the connection of the ac cable.
  6. [6] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 42 official manufacturer document quote verified if the ac cable is correctly connected and the alarm persists and affects the operation of the plant, contact the local power operator.
  7. [7] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 41 official manufacturer document quote verified the device is shut down.