Alarm 2077Off-Grid Output Overload
Name in the manufacturer's documentation (fault list): Off-Grid Output Overload
[1]
In plain words (editorial)
The off-grid (backup) output is overloaded or short-circuited, or the irradiance or battery is too low for the load. The manual says to check for a short circuit, check that the load does not exceed the rated power, and remove some loads; then clear the alarm.
When to call a service technician: If it persists with fewer loads, contact your installer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 68 official manufacturer document quote verified
2077 Off-Grid Output Overload
- [2] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 68 official manufacturer document quote verified
the output is overloaded or short-circuited.
- [3] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 68 official manufacturer document quote verified
the irradiance or battery is low.
- [4] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 68 official manufacturer document quote verified
check whether the device output is short-circuited.
- [5] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 68 official manufacturer document quote verified
check whether the device load exceeds the rated power.
- [6] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 68 official manufacturer document quote verified
if the irradiance or battery is low, remove some loads.
- [7] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 68 official manufacturer document quote verified
after the preceding problems are resolved, manually clear the alarm.