CH27AC Input Instant over Current Error
Name in the manufacturer's documentation (service manual): AC Input Instant over Current Error
[1]
In plain words (editorial)
Instant overcurrent at the AC input of the inverter PCB. The service manual names overload operation (pipe clogging, covering, EEV defect, refrigerant overcharge), compressor damage, abnormal input voltage, power line assembly problems or a damaged PCB.
When to call a service technician: Contact an LG-authorised service technician or your installer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
- PCB(Inverter) input current is over 100 A(peak) for 2 us[2]
- Overload operation (Pipe clogging/Covering/EEV defect/Ref. overcharge)[3]
- Compressor damage (Insulation damage/Motor damage)[4]
- Input voltage abnormal (L, N)[5]
- Power line assemble condition abnormal[6]
- PCB assembly 1 Damage (input current sensing part)[7]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
27 AC Input Instant over Current Error
- [2] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
PCB(Inverter) input current is over 100 A(peak) for 2 us
- [3] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Overload operation (Pipe clogging/Covering/EEV defect/Ref. overcharge)
- [4] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Compressor damage (Insulation damage/Motor damage)
- [5] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Input voltage abnormal (L,N)
- [6] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Power line assemble condition abnormal
- [7] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
PCB assembly 1 Damage (input current sensing part)