LG · Heat pumps · LG Therma V Monobloc (air-to-water heat pump)

CH61High temperature in Cond. Pipe

Name in the manufacturer's documentation (service manual): High temperature in Cond. Pipe[1]

In plain words (editorial)

High temperature in the condenser pipe. The service manual names overload operation (outdoor fan obstructed, screened or blocked), a contaminated heat exchanger, a displaced EEV connector or a poor condenser pipe sensor.

When to call a service technician: Keep the outdoor unit clean and unobstructed; if the code repeats, contact an LG-authorised service technician or your installer.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified 61 High temperature in Cond. Pipe
  2. [2] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified Overload operation (Outdoor fan constraint, screened, blocked)
  3. [3] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified Unit heat exchanger contaminated
  4. [4] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified EEV connector displaced / poor EEV assembly
  5. [5] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified Poor Cond. Pipe sensor assembly / burned
  6. [6] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified Check outdoor fan constraint / screened / flow structure
  7. [7] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified Check if refrigerant overcharged
  8. [8] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified Check the status of EEV assembly
  9. [9] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 279 official manufacturer document quote verified Check the status of sensor assembly / burn