Mitsubishi Electric · Split air conditioners · Mitsubishi Electric MSZ-AP (wall-mounted split, R32)
2 blinksIndoor coil thermistor / Room temperature thermistor
Name in the manufacturer's documentation (service manual): Indoor coil thermistor / Room temperature thermistor
[1]
In plain words (editorial)
The indoor coil thermistor or the room temperature thermistor is short- or open-circuited. The checks in the service manual are for a qualified air-conditioning technician.
When to call a service technician: Contact an authorised Mitsubishi Electric service technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Steps given by the manufacturer (source text)
- Refer to the characteristics of indoor coil thermistor and room temperature thermistor (10-7).[4]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Mitsubishi Electric – Service Manual: Indoor unit MSZ-AP25VG(K) … MSZ-AP71VG(K) (OBH788 REVISED EDITION-B) (OBH788 REVISED EDITION-B) , p. 34 official manufacturer document quote verified
2-time blink
- [2] Mitsubishi Electric – Service Manual: Indoor unit MSZ-AP25VG(K) … MSZ-AP71VG(K) (OBH788 REVISED EDITION-B) (OBH788 REVISED EDITION-B) , p. 34 official manufacturer document quote verified
The indoor coil or the room temperature ther-
- [3] Mitsubishi Electric – Service Manual: Indoor unit MSZ-AP25VG(K) … MSZ-AP71VG(K) (OBH788 REVISED EDITION-B) (OBH788 REVISED EDITION-B) , p. 31 official manufacturer document quote verified
is detected every 8 seconds during operation.
- [4] Mitsubishi Electric – Service Manual: Indoor unit MSZ-AP25VG(K) … MSZ-AP71VG(K) (OBH788 REVISED EDITION-B) (OBH788 REVISED EDITION-B) , p. 34 official manufacturer document quote verified
Refer to the characteristics of