Panasonic · Heat pumps · Panasonic Aquarea Monobloc, generation H
H23Indoor refrigerant liquid temperature sensor abnormality
Name in the manufacturer's documentation (service manual): Indoor refrigerant liquid temperature sensor abnormality
[1]
In plain words (editorial)
The controller gets an implausible reading from the refrigerant liquid temperature sensor – usually a connector, the sensor itself or the PCB.
When to call a service technician: Ask the installer to check the sensor, its connector and wiring (power off first).
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – Mono Bloc Unit WH-MDC05H3E5 / 07 / 09 (PAPAMY1709003CE) , p. 145 official manufacturer document quote verified
H23 Indoor refrigerant liquid temperature sensor abnormality
- [2] Service Manual – Mono Bloc Unit WH-MDC05H3E5 / 07 / 09 (PAPAMY1709003CE) , p. 150 official manufacturer document quote verified
During startup and operation of cooling and heating, the temperatures detected by the indoor refrigerant liquid temperature sensor are used to determine sensor error.
- [3] Service Manual – Mono Bloc Unit WH-MDC05H3E5 / 07 / 09 (PAPAMY1709003CE) , p. 150 official manufacturer document quote verified
Continue for 5 seconds.
- [4] Service Manual – Mono Bloc Unit WH-MDC05H3E5 / 07 / 09 (PAPAMY1709003CE) , p. 150 official manufacturer document quote verified
Faulty connector connection.
- [5] Service Manual – Mono Bloc Unit WH-MDC05H3E5 / 07 / 09 (PAPAMY1709003CE) , p. 150 official manufacturer document quote verified
Faulty sensor.
- [6] Service Manual – Mono Bloc Unit WH-MDC05H3E5 / 07 / 09 (PAPAMY1709003CE) , p. 150 official manufacturer document quote verified
Faulty indoor unit PCB (main).