Panasonic · Heat pumps · Panasonic Aquarea Bi-bloc (split), generation H
H70Back-up heater OLP abnormality
Name in the manufacturer's documentation (service manual): Back-up heater OLP abnormality
[1]
In plain words (editorial)
The backup electric heater gets no power or its overload protector (OLP) has opened.
When to call a service technician: The backup heater is mains-powered – checks are for the installer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 153 manufacturer document – copy from a distributor quote verified
H70 Back-up heater OLP abnormality
- [2] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 172 manufacturer document – copy from a distributor quote verified
During operation of indoor backup heater, when no power supplies to indoor backup heater or OLP open circuit.
- [3] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 172 manufacturer document – copy from a distributor quote verified
Continue for 60 seconds.
- [4] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 172 manufacturer document – copy from a distributor quote verified
Faulty power supply connector connection.
- [5] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 172 manufacturer document – copy from a distributor quote verified
Faulty connector connection.
- [6] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 172 manufacturer document – copy from a distributor quote verified
Faulty indoor backup heater overload protector (OLP).
- [7] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 172 manufacturer document – copy from a distributor quote verified
Faulty indoor unit PCB (main).