F15Outdoor fan motor lock abnormality

Name in the manufacturer's documentation (service manual): Outdoor fan motor lock abnormality[1]

This page only quotes the original English documentation. A plain-language explanation has not been written yet, so the page is not indexed by search engines.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 164 manufacturer document – copy from a distributor quote verified f15 outdoor fan motor lock abnormality
  2. [2] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 194 manufacturer document – copy from a distributor quote verified feedback of rotation > 2550 rpm or < 50 rpm
  3. [3] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 194 manufacturer document – copy from a distributor quote verified abnormality judgment: continue 2 times in 30 minutes.
  4. [4] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 194 manufacturer document – copy from a distributor quote verified Operation stop due to short circuit inside the fan motor winding.
  5. [5] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 194 manufacturer document – copy from a distributor quote verified Operation stop due to breaking of wire inside the fan motor.
  6. [6] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 194 manufacturer document – copy from a distributor quote verified Operation stop due to breaking of fan motor lead wires.
  7. [7] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 194 manufacturer document – copy from a distributor quote verified Operation stop due to fan motor Hall IC malfunction.
  8. [8] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 194 manufacturer document – copy from a distributor quote verified Operation error due to faulty outdoor unit PCB.