Skip to content
EN

Panasonic · Heat pumps · Panasonic Aquarea Monobloc, generation J (R32)

H20Water pump abnormality

Name in the manufacturer's documentation (service manual): Water pump abnormality[1]

In plain words (editorial)

The water pump is not working correctly – the unit detects an abnormal pump speed. The service manual lists faults in the pump motor or its wiring.

When to call a service technician: Call the installer – the checks are done inside the unit.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 164 manufacturer document – copy from a distributor quote verified h20 water pump abnormality continue for 10 sec.
  2. [2] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 168 manufacturer document – copy from a distributor quote verified feedback of rotation > 6,000rpm or < 1,000rpm
  3. [3] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 168 manufacturer document – copy from a distributor quote verified abnormality judgment: continue for 5 seconds.
  4. [4] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 164 manufacturer document – copy from a distributor quote verified h20 water pump abnormality continue for 10 sec.
  5. [5] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 168 manufacturer document – copy from a distributor quote verified Operation stop due to short circuit inside the water pump motor winding.
  6. [6] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 168 manufacturer document – copy from a distributor quote verified Operation stop due to breaking of wire inside the water pump motor.
  7. [7] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 168 manufacturer document – copy from a distributor quote verified Operation stop due to breaking of water pump lead wires.
  8. [8] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 168 manufacturer document – copy from a distributor quote verified Operation stop due to water pump motor IPM malfunction.
  9. [9] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 168 manufacturer document – copy from a distributor quote verified Operation error due to faulty indoor unit PCB.