From the manufacturer's documentation (English source wording, with page)

  1. Water pressure gauge – main component 4[1]
  2. Pressure gauge reading should be in between 0.05 mpa and 0.3 mpa[2]
  3. Pressure relief valve check – clacking sound[3]
  4. Expansion vessel 6 l, initial pressure 1 bar[4]
  5. Total water volume below 150 l without antifreeze, otherwise extra vessel[5]

⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 37 manufacturer document – copy from a distributor quote verified 4 water pressure gauge
  2. [2] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 63 manufacturer document – copy from a distributor quote verified pressure gauge reading should be in between 0.05 mpa and 0.3 mpa
  3. [3] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 62 manufacturer document – copy from a distributor quote verified if you do not hear a clacking sound
  4. [4] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 62 manufacturer document – copy from a distributor quote verified with 6 l air capacity and initial pressure of 1 bar
  5. [5] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 62 manufacturer document – copy from a distributor quote verified total amount of water in the system should be below