Panasonic · Heat pumps · Panasonic Aquarea Bi-bloc (split), generation L (R290)
F41PFC control
Name in the manufacturer's documentation (service manual): PFC control
[1]
This page only quotes the original English documentation. A plain-language explanation has not been written yet, so the page is not indexed by search engines.
For technicians
Detection conditions (source text)
Possible causes (source text)
Safety notes from the documentation
- Always switch off the power before remove and connect the component.[7]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 190 manufacturer document – copy from a distributor quote verified
F41 PFC control
- [2] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 235 manufacturer document – copy from a distributor quote verified
During operation of cooling and heating, when the PFC protection circuitry in the outdoor unit PCB (main) senses abnormal high DC voltage level.
- [3] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 235 manufacturer document – copy from a distributor quote verified
Continue 4 times in 10 minutes.
- [4] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 235 manufacturer document – copy from a distributor quote verified
Power supply surge.
- [5] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 235 manufacturer document – copy from a distributor quote verified
Compressor windings not uniform.
- [6] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 235 manufacturer document – copy from a distributor quote verified
Faulty outdoor unit PCB (main).
- [7] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 235 manufacturer document – copy from a distributor quote verified
always switch off the power before remove and connect the component.