Panasonic · Heat pumps · Panasonic Aquarea T-CAP Monobloc, generation J (R32)
H12Indoor/Outdoor capacity unmatched
Name in the manufacturer's documentation (service manual): Indoor/Outdoor capacity unmatched
[1]
In plain words (editorial)
The outdoor unit and the indoor unit do not match each other (capacity unmatched) – for example a wrong model combination or a wrong PCB.
When to call a service technician: This is fixed by the installer – the units or PCB must match the specification.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 164 official manufacturer document quote verified
H12 Indoor/Outdoor capacity unmatched
- [2] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 166 official manufacturer document quote verified
During startup operation of cooling and heating, the capability rank of indoor checked by the outdoor is used to determine connection capability rank abnormality.
- [3] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 166 official manufacturer document quote verified
Continue for 90 seconds.
- [4] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 166 official manufacturer document quote verified
Wrong model interconnected.
- [5] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 166 official manufacturer document quote verified
Wrong indoor unit or outdoor unit PCB (main) used.
- [6] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 166 official manufacturer document quote verified
Faulty indoor unit or outdoor unit PCB (main).