Panasonic · Heat pumps · Panasonic Aquarea T-CAP Monobloc, generation J (R32)
H20Water pump abnormality
Name in the manufacturer's documentation (service manual): Water pump abnormality
[1]
In plain words (editorial)
The water pump is not working correctly – the unit detects an abnormal pump speed. The service manual lists faults in the pump motor or its wiring.
When to call a service technician: Call the installer – the checks are done inside the unit.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
- Operation stop due to short circuit inside the water pump motor winding.[4]
- Operation stop due to breaking of wire inside the water pump motor.[5]
- Operation stop due to breaking of water pump lead wires.[6]
- Operation stop due to water pump motor IPM malfunction.[7]
- Operation error due to faulty indoor unit PCB.[8]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 164 official manufacturer document quote verified
H20 Water pump abnormality
- [2] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 168 official manufacturer document quote verified
During startup and operation of cooling and heating, the rotation speed detected by the IPM of water pump motor during water pump operation is used to determine abnormal water pump (feedback of rotation > 6,000rpm or < 7…
- [3] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 168 official manufacturer document quote verified
Continue for 5 seconds.
- [4] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 168 official manufacturer document quote verified
Operation stop due to short circuit inside the water pump motor winding.
- [5] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 168 official manufacturer document quote verified
Operation stop due to breaking of wire inside the water pump motor.
- [6] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 168 official manufacturer document quote verified
Operation stop due to breaking of water pump lead wires.
- [7] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 168 official manufacturer document quote verified
Operation stop due to water pump motor IPM malfunction.
- [8] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 168 official manufacturer document quote verified
Operation error due to faulty indoor unit PCB.