Panasonic · Heat pumps · Panasonic Aquarea T-CAP Monobloc, generation J (R32)
H64Refrigerant high pressure abnormality
Name in the manufacturer's documentation (service manual): Refrigerant high pressure abnormality
[1]
In plain words (editorial)
The heat pump has detected a fault of the outdoor high pressure sensor (its reading is used to detect a sensor error). The service manual names a faulty connector connection, the sensor itself or the outdoor unit PCB as causes.
When to call a service technician: Contact the installer or Panasonic service – the sensor, its connector and the PCB are checked inside the unit.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 164 official manufacturer document quote verified
H64 Refrigerant high pressure abnormality
- [2] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 179 official manufacturer document quote verified
During operation of cooling and heating, when the outdoor high pressure sensor output signal is 0 Vdc or 5 Vdc.
- [3] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 179 official manufacturer document quote verified
Continue 4 times in 20 minutes.
- [4] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 179 official manufacturer document quote verified
Faulty connector connection.
- [5] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 179 official manufacturer document quote verified
Faulty sensor.
- [6] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 179 official manufacturer document quote verified
Faulty outdoor unit PCB (main).