Panasonic · Panasonic Aquarea T-CAP Monobloc, generation J (R32) · Procedure
Aquarea T-CAP J monobloc: where the error code appears, how to reset it and where the error history is
Summary (editorial)
When a fault is detected the unit stops, the OFF/ON LED blinks and the code is shown. A reset does not remove the cause; the code is stored in memory.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
From the manufacturer's documentation (English source wording, with page)
- When abnormality occur during operation, the system will stop operation, and OFF/ON control panel LED will blink and error code will display on the control panel[1]
- Press the quick menu button to display the quick menu[2]
- Quick menu items include Error reset[3]
- Even error code is reset by turning off power supply or by selecting Error reset, if the system abnormality is still unrepaired, system will again stop operation, the OFF/ON LED will again blink and error code will be displayed[4]
- The error code will store in IC memory[5]
- Error history: the most recent error code is displayed at the top; refer to troubleshooting for error codes[6]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 162 official manufacturer document quote verified
off/on control panel led will blink and error code will display on the control panel.
- [2] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 19 official manufacturer document quote verified
press to display the quick menu.
- [3] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 19 official manufacturer document quote verified
force defrost error reset r/c lock
- [4] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 162 official manufacturer document quote verified
even error code is reset by turning off power supply or by selecting error reset,
- [5] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 162 official manufacturer document quote verified
the error code will store in ic memory.
- [6] Service Manual – Mono Bloc Unit WH-MXC09J3E5 / WH-MXC12J6E5 (Aquarea T-CAP, R32) (PAPAMY2101001CE) , p. 21 official manufacturer document quote verified
the most recent error code is