Rotenso · Split air conditioners · Rotenso Imoto wall-mounted inverter split
PC 01Over voltage or over low voltage protection
Name in the manufacturer's documentation (service manual): Over voltage or over low voltage protection
[1]
In plain words (editorial)
Overvoltage or undervoltage protection: the unit detected an abnormal rise or drop of the supply voltage.
When to call a service technician: If it repeats, have the supply and the unit checked by a technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
- Abnormal increases or decreases in voltage are detected by checking the specified voltage detection circuit.[2]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Rotenso Imoto Series – IDU & ODU Units Service Manual (I21Xi, I26X, I35X, I50X, I70X), EN , p. 133 manufacturer document – copy from a distributor quote verified
Over voltage or over low voltage protection
- [2] Rotenso Imoto Series – IDU & ODU Units Service Manual (I21Xi, I26X, I35X, I50X, I70X), EN , p. 159 manufacturer document – copy from a distributor quote verified
Abnormal increases or decreases in voltage are detected by checking the specified voltage detection circuit.
- [3] Rotenso Imoto Series – IDU & ODU Units Service Manual (I21Xi, I26X, I35X, I50X, I70X), EN , p. 159 manufacturer document – copy from a distributor quote verified
Power supply wires
- [4] Rotenso Imoto Series – IDU & ODU Units Service Manual (I21Xi, I26X, I35X, I50X, I70X), EN , p. 159 manufacturer document – copy from a distributor quote verified
IPM module board
- [5] Rotenso Imoto Series – IDU & ODU Units Service Manual (I21Xi, I26X, I35X, I50X, I70X), EN , p. 159 manufacturer document – copy from a distributor quote verified
- [6] Rotenso Imoto Series – IDU & ODU Units Service Manual (I21Xi, I26X, I35X, I50X, I70X), EN , p. 159 manufacturer document – copy from a distributor quote verified
Reactor