Samsung · Samsung EHS Mono R32 (air-to-water monobloc) · Maintenance
Samsung EHS Mono: water pressure and the strainer filter
Summary (editorial)
The manual gives the water pressure guidance and explains why the strainer (mesh) filter must be cleaned.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
From the manufacturer's documentation (English source wording, with page)
- The nominal water pressure in the system should remain about 1.0 bar at all times to avoid air entering the water system[1]
- The water pressure indicated on the manometer will vary depending on the water temperature[2]
- The strainer (water filter) must be cleaned after flushing the pipes, and it should be cleaned periodically; replace when necessary[3]
- The minimum required water flow for operation is 16 liters/min; otherwise the unit can stop due to a lack of water[4]
- The pressure relief valve prevents abnormal water pressure by opening at 3.0 bar[5]
- It is recommended that annually a competent person inspects and cleans the line strainer and checks the relief valves[6]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Samsung EHS R-32 Mono Outdoor (AE***RXYDEG/DGG) – Installation manual (DB68-08408A-07 (2024-01-10)) , p. 27 official manufacturer document quote verified
the nominal water pressure in the system should remain about 1.0 bar at all times to avoid air entering the water system.
- [2] Samsung EHS R-32 Mono Outdoor (AE***RXYDEG/DGG) – Installation manual (DB68-08408A-07 (2024-01-10)) , p. 27 official manufacturer document quote verified
(the water pressure indicated on the manometer will vary depending on the water temperature)
- [3] Samsung EHS R-32 Mono Outdoor (AE***RXYDEG/DGG) – Installation manual (DB68-08408A-07 (2024-01-10)) , p. 27 official manufacturer document quote verified
the strainer(water filter) must be cleaned after flushing the pipes, and it should be cleaned periodically.
- [4] Samsung EHS R-32 Mono Outdoor (AE***RXYDEG/DGG) – Installation manual (DB68-08408A-07 (2024-01-10)) , p. 27 official manufacturer document quote verified
the minimum required water flow for operation is 16 liters/min
- [5] Samsung EHS R-32 Mono Outdoor (AE***RXYDEG/DGG) – Installation manual (DB68-08408A-07 (2024-01-10)) , p. 32 official manufacturer document quote verified
opening at 3.0 bar.
- [6] Samsung EHS R-32 Mono Outdoor (AE***RXYDEG/DGG) – Installation manual (DB68-08408A-07 (2024-01-10)) , p. 47 official manufacturer document quote verified
it is recommended that annually a competent person