F.022Building circuit: Water pressure too low

Name in the manufacturer's documentation (service manual): Building circuit: Water pressure too low[1]

In plain words (editorial)

The water pressure in the heating (building) circuit is too low. The manual names pressure loss caused by leaks or air pockets, or a defective pressure sensor. Topping up the water and purging the system are part of the manual's fix.

When to call a service technician: If you are not sure how to top up the system, or the pressure keeps dropping (possible leak), contact a heating engineer.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified Building circuit: Water press. too
  2. [2] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified due to leakages or air pockets
  3. [3] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified Building circuit pressure sensor
  4. [4] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified Check the building circuit for leaks
  5. [5] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified Top up with water, purge
  6. [6] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified Check the quality of the plug contact
  7. [7] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified Replace the pressure sensor