Vaillant · Heat pumps · Vaillant aroTHERM plus with uniTOWER plus
F.752Fault: Frequency converter
Name in the manufacturer's documentation (service manual): Fault: Frequency converter
[1]
In plain words (editorial)
Fault of the frequency converter (inverter) that drives the compressor – an internal electronics fault, or a mains voltage outside 70 V–282 V. The manual says the mains voltage must be between 195 V and 253 V.
When to call a service technician: Contact a competent heating engineer (installer or Vaillant customer service).
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
F.752 Fault: Frequency converter
- [2] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
Internal electronics fault on the in- verter PCB
- [3] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
Mains voltage outside of 70 V–282 V
- [4] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
Check the integrity of the power sup- ply cables and compressor connec- tion cables The plugs must audibly click into place
- [5] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
Check the cable
- [6] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
Check the mains voltage The mains voltage must be between 195 V and 253 V
- [7] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
Check the phases
- [8] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 62 official manufacturer document quote verified
Replace the frequency converter, if required