Vaillant · Heat pumps · Vaillant aroTHERM plus with uniTOWER plus
M.32Building circuit: Waterpress. Low
Name in the manufacturer's documentation (service manual): Building circuit: Waterpress. Low
[1]
In plain words (editorial)
The water pressure in the building heating circuit is too low. The manual lists pressure loss through leaks or air pockets, or a defective pressure sensor; it says to check the circuit for leaks, top up with heating water and purge (bleed) it.
When to call a service technician: If you are not sure how to top up your system, or the pressure keeps dropping, call the installer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified
M.32 Building circuit: Waterpress. Low
- [2] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified
Pressure loss in the building circuit due to leakages or air pockets
- [3] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified
Building circuit pressure sensor is defective
- [4] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified
Check the building circuit for leaks, top up with heating water and purge
- [5] Vaillant uniTOWER plus VIH QW 190/6 E – Operating, installation and maintenance instructions (0020291525_05) (0020291525_05) , p. 59 official manufacturer document quote verified
check that the pressure sensor is working correctly and, if required, replace the pressure sensor