Skip to content
EN

Daikin · Heat pumps · Daikin Altherma 3 R F (split heat pump, R32)

AC-00Booster heater overheated

Name in the manufacturer's documentation (service manual): Booster heater overheated[1]

In plain words (editorial)

The booster heater (in the hot water tank) overheated. The manual names an open jumper on X21A of the hydro PCB, too low water flow, air in the water circuit, an external heat source raising the water temperature, or wrong booster heater settings.

When to call a service technician: Contact your installer or Daikin dealer.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Daikin Altherma 3 R F – ERGA04~08E + EHVH/X04+08S18+23E – Installer reference guide (4P629086-1D (2024.04)) , p. 254 official manufacturer document quote verified AC-00 Booster heater overheated
  2. [2] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified open jumper on x21a on hydro pcb.
  3. [3] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified faulty hydro pcb.
  4. [4] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified water flow is too low.
  5. [5] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified air in the water circuit.
  6. [6] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified increased water temperature due to an external heat source.
  7. [7] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified faulty booster heater settings.
  8. [8] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified check that the bridge connector is correctly connected to x21a of the hydro pcb.
  9. [9] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified perform a check of the hydro pcb.
  10. [10] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified check the water flow.
  11. [11] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified purge the water circuit.
  12. [12] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 31 manufacturer document – copy from a distributor quote verified check the water circuit for an external heat source.