U4-00Indoor/outdoor unit communication problem

Name in the manufacturer's documentation (service manual): Indoor/outdoor unit communication problem[1]

In plain words (editorial)

Communication problem between the indoor and outdoor units. The manual names a disturbed power supply, faulty wiring between the outdoor unit, indoor unit and DHW tank, a faulty main PCB or fan motor.

When to call a service technician: Contact your installer or Daikin dealer.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Daikin Altherma 3 R F – ERGA04~08E + EHVH/X04+08S18+23E – Installer reference guide (4P629086-1D (2024.04)) , p. 255 official manufacturer document quote verified U4-00 Indoor/outdoor unit communication problem
  2. [2] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified ▪ faulty or disturbance of the power supply (power supply must be within range of nominal operating voltage ±4%), ▪ power drop, ▪ short circuit.
  3. [3] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified faulty wiring between the outdoor unit, indoor unit and domestic hot water tank.
  4. [4] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified faulty main pcb.
  5. [5] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified faulty outdoor unit fan motor.
  6. [6] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified check if the power supply is compliant with the regulations.
  7. [7] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified perform a check of the power supply, connections, wiring,… between the outdoor unit, indoor unit and (separate) domestic hot water tank (if applicable).
  8. [8] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified perform a check of the main pcb.
  9. [9] Daikin – Service manual Daikin Altherma 3 R F + W, ESIE20-13C – 2022.09 (PDF copy on installer site cncpompyciepla.pl) (ESIE20-13C) , p. 60 manufacturer document – copy from a distributor quote verified perform a check of the outdoor unit fan motor.