Gree · Split air conditioners · Gree Pular (wall-mounted split, R32)
FCMalfunction of micro switch
Name in the manufacturer's documentation (service manual): Malfunction of micro switch
[1]
In plain words (editorial)
Malfunction of the micro switch – the service manual names a blocked sliding door or a fault of its photoelectric inspection panel. In cooling/dry mode the compressor stops while the indoor fan keeps running; in heating all loads stop.
When to call a service technician: Call a service technician if the code returns after switching the unit off and on.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
What the device does (source text)
- Cool/Dry: compressor stops operation, while indoor fan operates; Heat: all loads stops operation[4]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 101 manufacturer document – copy from a distributor checked manually
Malfunction of micro switch
- [2] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 101 manufacturer document – copy from a distributor quote verified
The sliding door is blocked
- [3] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 101 manufacturer document – copy from a distributor quote verified
Malfunction of the photoelectric inspection panel of sliding door
- [4] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 100 manufacturer document – copy from a distributor quote verified
Cool/Dry: compressor stops operation, while indoor fan operates; Heat: all loads stops operation