Gree · Split air conditioners · 54 codes · 51 with plain-language explanation
Error codes
- C4 Malfunction of jumper cap of outdoor unit with plain-language explanation
- C5 Malfunction of jumper cap with plain-language explanation
- E1 High pressure protection of system with plain-language explanation
- E2 Evaporator anti-freezing protection with plain-language explanation
- E3 Low pressure/low system pressure protection/compressor low pressure protection with plain-language explanation
- E4 High discharge temperature protection of compressor with plain-language explanation
- E5 AC overcurrent protection with plain-language explanation
- E6 Communication malfunction between indoor unit and outdoor unit with plain-language explanation
- E7 Mode shock / system mode shock with plain-language explanation
- E8 High temperature prevention protection with plain-language explanation
- E9 Anti cold air protection with plain-language explanation
- EE Malfunction of EEPROM with plain-language explanation
- F0 Refrigerant insufficient protection, cut-off protection of refrigerant with plain-language explanation
- F1 Indoor ambient temperature sensor is open/short-circuited with plain-language explanation
- F2 Indoor evaporator temperature sensor is open/short-circuited with plain-language explanation
- F3 Outdoor ambient temperature sensor is open/short-circuited with plain-language explanation
- F4 Outdoor condenser temperature sensor is open/short-circuited with plain-language explanation
- F5 Outdoor air discharge temperature sensor is open/short-circuited with plain-language explanation
- FC Malfunction of micro switch with plain-language explanation
- Fo Refrigerant-recovery mode with plain-language explanation
- H3 Overload protection of compressor with plain-language explanation
- H4 System is abnormal with plain-language explanation
- H5 IPM protection with plain-language explanation
- H6 No feedback from indoor unit's motor with plain-language explanation
- H7 Desynchronizing of compressor with plain-language explanation
- HC PFC protection with plain-language explanation
- HE Demagnetization protection of compressor with plain-language explanation
- JF Communication malfunction between indoor unit and inspection board with plain-language explanation
- L1 Malfunction of humidity sensor with plain-language explanation
- L3 Malfunction of outdoor fan/malfunction of DC motor with plain-language explanation
- L9 High power protection with plain-language explanation
- LA Malfunction of outdoor fan/malfunction of DC motor (fan 2) with plain-language explanation
- LC Start-up failed with plain-language explanation
- LP Indoor unit and outdoor unit can be matched with each other with plain-language explanation
- Ld Lost phase with plain-language explanation
- P5 Over-phase current protection of compressor with plain-language explanation
- P6 Communication malfunction between the drive board and the main board with plain-language explanation
- P7 Circuit malfunction of module temperature sensor with plain-language explanation
- P8 Module overheating protection with plain-language explanation
- PF Malfunction of ambient temperature sensor of drive board with plain-language explanation
- PH DC bus voltage is too high source text only
- PL DC bus voltage is too low source text only
- PU Charging malfunction of capacitor source text only
- U1 Phase current detection circuit malfunction of compressor with plain-language explanation
- U2 Lost phase protection of compressor with plain-language explanation
- U3 DC bus voltage drop malfunction with plain-language explanation
- U5 Current detection malfunction of unit with plain-language explanation
- U7 4-way valve is abnormal with plain-language explanation
- U8 Malfunction of zero-crossing signal of indoor unit with plain-language explanation
- U9 Zero-crossing malfunction of outdoor unit with plain-language explanation
- b5 Liquid valve temperature sensor is ON / short-circuited with plain-language explanation
- b7 Gas valve temperature sensor is ON / short-circuited with plain-language explanation
- oE Undefined outdoor unit error with plain-language explanation
- rF Malfunction of RF module with plain-language explanation