Gree · Split air conditioners · Gree Pular (wall-mounted split, R32)
P8Module overheating protection
Name in the manufacturer's documentation (service manual): Module overheating protection
[1]
In plain words (editorial)
The power module overheated. The service manual lists blocked air inlet/outlet or a dirty condenser of the outdoor unit, a loose IPM screw or a damaged outdoor main board.
When to call a service technician: Keep the outdoor unit clear; if the code returns, call a service technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
What the device does (source text)
- Cool: compressor stops operation, while indoor fan operates; Heat: all loads stops operation[6]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor checked manually
Module overheating pro-
- [2] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Air inlet / air outlet of outdoor unit are blocked by filth or dirt
- [3] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Condenser of outdoor unit is blocked by filth or dirt
- [4] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
IPM screw of main board is not tightened
- [5] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Main board of outdoor unit is damaged
- [6] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Cool: compressor stops operation, while indoor fan operates; Heat: all loads stops operation