Skip to content
EN

Gree · Split air conditioners · Gree Pular (wall-mounted split, R32)

LAMalfunction of outdoor fan/malfunction of DC motor (fan 2)

Name in the manufacturer's documentation (service manual): Malfunction of outdoor fan/malfunction of DC motor (fan 2)[1]

In plain words (editorial)

Malfunction of outdoor fan 2 (DC motor). The service manual names a condenser or air inlet/outlet blocked by dirt, a blocked or loose fan, a damaged motor or motor wire, or a damaged outdoor main board.

When to call a service technician: Check that the outdoor unit is not blocked by dirt or debris; if the code returns, call a service technician.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor checked manually LA indicates fan 2
  2. [2] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified Outdoor condenser, air inlet and air outlet are blocked by filth or dirt
  3. [3] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified Fan is blocked or loosened
  4. [4] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified Motor or connection wire of motor is damaged
  5. [5] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified Main board of outdoor unit is damaged; (As for dual-outdoor fan, L3 indicates fan 1; LA indicates fan 2)
  6. [6] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified Cool/Dry: all loads stops operation except indoor fan. Heat: all loads stops operation