Gree · Split air conditioners · Gree Pular (wall-mounted split, R32)
L3Malfunction of outdoor fan/malfunction of DC motor
Name in the manufacturer's documentation (service manual): Malfunction of outdoor fan/malfunction of DC motor
[1]
In plain words (editorial)
The outdoor fan (DC motor) has a malfunction. The service manual lists a dirty or blocked condenser, air inlet or outlet, a blocked or loose fan, the motor or its wire, or the outdoor main board.
When to call a service technician: Make sure nothing blocks the outdoor unit (without opening it); otherwise call a service technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
What the device does (source text)
- Cool/Dry: all loads stops operation except indoor fan. Heat: all loads stops operation[6]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor checked manually
Malfunction of outdoor fan/
- [2] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified
Outdoor condenser, air inlet and air outlet are blocked by filth or dirt
- [3] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified
Fan is blocked or loosened
- [4] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified
Motor or connection wire of motor is damaged
- [5] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified
Main board of outdoor unit is damaged; (As for dual-outdoor fan, L3 indicates fan 1; LA indicates fan 2)
- [6] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 99 manufacturer document – copy from a distributor quote verified
Cool/Dry: all loads stops operation except indoor fan. Heat: all loads stops operation