Gree · Split air conditioners · Gree Pular (wall-mounted split, R32)
oEUndefined outdoor unit error
Name in the manufacturer's documentation (service manual): Undefined outdoor unit error
[1]
In plain words (editorial)
Undefined outdoor unit error. The service manual first names an outdoor temperature outside the unit's operating range, then compressor wiring, compressor start-up or main board problems.
When to call a service technician: If it appears in normal weather, call a service technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
What the device does (source text)
- Cool: compressor and outdoor fan stops operation, while indoor fan operates; Heat: compressor, outdoor fan and indoor fan stop operation[7]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor checked manually
Undefined outdoor unit er-
- [2] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Outdoor ambient temperature exceeds the operation range of unit (e.g.: less than 20°C or more than 60°C for cooling; more than 30°C for heating)
- [3] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Are wires of compressor not connected tightly?
- [4] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Failure startup of compressor?
- [5] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Is compressor damaged?
- [6] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Is main board damaged?
- [7] Gree Electric Appliances – Service Manual, wall-mounted R32 GWH..AG.. (Pular) and related (copy from distributor Gree Climat, Ukraine) , p. 102 manufacturer document – copy from a distributor quote verified
Cool: compressor and outdoor fan stops operation, while indoor fan operates; Heat: compressor, outdoor fan and indoor fan stop operation