Growatt · PV inverters · Growatt MOD TL3-X (three-phase grid inverter, 3–15 kW)

Error 203PV isolation Low

Name in the manufacturer's documentation (user manual): PV isolation Low[1]

In plain words (editorial)

The insulation resistance of the PV side is too low – current may be leaking to earth from the cables or panels. The manual says to check, after shutdown, whether the panel frames are reliably grounded.

When to call a service technician: If the message stays, the installer must test the PV insulation; contact the manufacturer if needed.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.