Huawei · PV inverters · Huawei SUN2000-KTL-M1 (three-phase inverter, 3–10 kW, battery-ready)
Alarm 2063Temperature High
Name in the manufacturer's documentation (fault list): Temperature High
[1]
In plain words (editorial)
The inverter is too hot. The manual names poor ventilation, a high ambient temperature, a blocked fan or heat sink, or abnormal operation of the device. The inverter shuts down.
When to call a service technician: Improve ventilation around the inverter. If it keeps happening, contact your installer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
Steps given by the manufacturer (source text)
What the device does (source text)
- The device is shut down.[8]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 54 official manufacturer document quote verified
2063 Temperature High
- [2] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 54 official manufacturer document quote verified
the device is installed in a place with poor ventilation.
- [3] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 54 official manufacturer document quote verified
the ambient temperature is too high.
- [4] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 54 official manufacturer document quote verified
the device works abnormally.
- [5] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 54 official manufacturer document quote verified
the fan airflow is obstructed or the heat sink is blocked.
- [6] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 55 official manufacturer document quote verified
check the ventilation and ambient temperature of the device installation position.
- [7] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 55 official manufacturer document quote verified
if the ventilation is poor or the ambient temperature is too high, improve the ventilation and heat dissipation.
- [8] Inverter Alarm Reference (Issue 14, 2026-06-15) (EDOC1100345192 Issue 14) , p. 54 official manufacturer document quote verified
the device is shut down.