LG · Heat pumps · LG Therma V Monobloc (air-to-water heat pump)
CH32High temperature in Discharge pipe of the inverter compressor
Name in the manufacturer's documentation (service manual): High temperature in Discharge pipe of the inverter compressor
[1]
In plain words (editorial)
The discharge pipe of the inverter compressor is too hot. The service manual names overload operation (outdoor fan obstructed, screened or blocked), refrigerant leakage (shortage), a poor discharge sensor or a displaced EEV connector.
When to call a service technician: Make sure nothing blocks or covers the outdoor unit; if the code repeats, contact an LG-authorised service technician or your installer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
32 High temperature in Discharge pipe of the inverter compressor
- [2] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Overload operation (Outdoor fan constraint, screened, blocked)
- [3] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Refrigerant leakage (insufficient)
- [4] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Poor INV Comp Discharge sensor
- [5] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
LEV connector displaced / poor LEV assembly
- [6] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Check outdoor fan constraint/ screened/ flow structure
- [7] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Check refrigerant leakage
- [8] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Check if the sensor is normal
- [9] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified
Check the status of EEV assembly