LG · Heat pumps · LG Therma V Monobloc (air-to-water heat pump)

CH32High temperature in Discharge pipe of the inverter compressor

Name in the manufacturer's documentation (service manual): High temperature in Discharge pipe of the inverter compressor[1]

In plain words (editorial)

The discharge pipe of the inverter compressor is too hot. The service manual names overload operation (outdoor fan obstructed, screened or blocked), refrigerant leakage (shortage), a poor discharge sensor or a displaced EEV connector.

When to call a service technician: Make sure nothing blocks or covers the outdoor unit; if the code repeats, contact an LG-authorised service technician or your installer.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified 32 High temperature in Discharge pipe of the inverter compressor
  2. [2] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified Overload operation (Outdoor fan constraint, screened, blocked)
  3. [3] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified Refrigerant leakage (insufficient)
  4. [4] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified Poor INV Comp Discharge sensor
  5. [5] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified LEV connector displaced / poor LEV assembly
  6. [6] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified Check outdoor fan constraint/ screened/ flow structure
  7. [7] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified Check refrigerant leakage
  8. [8] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified Check if the sensor is normal
  9. [9] LG Therma V Monobloc – Installation manual (MFL68026607 Rev.21) (MFL68026607 Rev.21_062126) , p. 278 official manufacturer document quote verified Check the status of EEV assembly