Panasonic · Heat pumps · Panasonic Aquarea Bi-bloc (split), generation H

H64Refrigerant high pressure abnormality

Name in the manufacturer's documentation (service manual): Refrigerant high pressure abnormality[1]

In plain words (editorial)

The heat pump has detected a fault of the outdoor high pressure sensor (its reading is used to detect a sensor error). The service manual names a faulty connector connection, the sensor itself or the outdoor unit PCB as causes.

When to call a service technician: Contact the installer or Panasonic service – the sensor, its connector and the PCB are checked inside the unit.

✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.

The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →

Sources

Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.

  1. [1] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 153 manufacturer document – copy from a distributor quote verified H64 Refrigerant high pressure abnormality
  2. [2] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 168 manufacturer document – copy from a distributor quote verified During operation of cooling and heating, when the outdoor high pressure sensor output signal is 0 Vdc or 5 Vdc.
  3. [3] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 168 manufacturer document – copy from a distributor quote verified Continue 4 times in 20 minutes.
  4. [4] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 168 manufacturer document – copy from a distributor quote verified Faulty connector connection.
  5. [5] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 168 manufacturer document – copy from a distributor quote verified Faulty sensor.
  6. [6] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 168 manufacturer document – copy from a distributor quote verified Faulty outdoor unit PCB (main).