Panasonic · Heat pumps · Panasonic Aquarea Bi-bloc (split), generation H
H65Abnormal deice water circulation
Name in the manufacturer's documentation (service manual): Abnormal deice water circulation
[1]
In plain words (editorial)
During defrost, water was flowing in the circuit when it should not (abnormal deice water circulation).
When to call a service technician: Call the installer – the checks are done inside the unit.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 153 manufacturer document – copy from a distributor quote verified
H65 Abnormal deice water circulation
- [2] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 169 manufacturer document – copy from a distributor quote verified
During startup and operation of deice (mode 2), the water flow (> 10l/min) detected by the water flow switch is used to determine deice circulation error.
- [3] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 169 manufacturer document – copy from a distributor quote verified
Continue for 10 seconds.
- [4] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 169 manufacturer document – copy from a distributor quote verified
Water flow in air-to-water heatpump indoor unit circuitry.
- [5] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 169 manufacturer document – copy from a distributor quote verified
Faulty indoor unit water flow switch.
- [6] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 169 manufacturer document – copy from a distributor quote verified
Faulty indoor unit water pump.
- [7] Service Manual – WH-SDC03/05/07/09H3E5-1 + WH-UD03/05/07/09HE5-1 (PAPAMY1703036CE) , p. 169 manufacturer document – copy from a distributor quote verified
Faulty indoor unit PCB.