Panasonic · Heat pumps · Panasonic Aquarea Monobloc, generation J (R32)
H43Abnormal Zone 1 sensor
Name in the manufacturer's documentation (service manual): Abnormal Zone 1 sensor
[1]
In plain words (editorial)
The controller gets an implausible reading from the zone 1 water temperature sensor. Typical causes listed by the manual are a loose connector, a faulty sensor or a faulty indoor sub PCB.
When to call a service technician: Ask the installer to measure the zone 1 sensor and check its wiring (power off first).
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
- Continue for 5 seconds.[2]
Possible causes (source text)
Safety notes from the documentation
- Always switch off the power before remove and connect the component.[6]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 164 manufacturer document – copy from a distributor quote verified
Abnormal Zone 1 sensor
- [2] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 176 manufacturer document – copy from a distributor quote verified
Continue for 5 seconds.
- [3] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 176 manufacturer document – copy from a distributor quote verified
Faulty connector connection.
- [4] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 176 manufacturer document – copy from a distributor quote verified
Faulty buffer tank sensor.
- [5] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 176 manufacturer document – copy from a distributor quote verified
Faulty indoor sub PCB.
- [6] Service Manual – Mono Bloc Unit WH-MDC05J3E5 / WH-MDC07J3E5 / WH-MDC09J3E5 (PAPAMY2003034CE) , p. 176 manufacturer document – copy from a distributor quote verified
always switch off the power before remove and connect the component.