Panasonic · Heat pumps · Panasonic Aquarea Bi-bloc (split), generation L (R290)
H21Abnormal water pressure
Name in the manufacturer's documentation (service manual): Abnormal water pressure
[1]
In plain words (editorial)
The unit detected abnormal water pressure in the heating circuit.
When to call a service technician: Check the system pressure gauge if you have one; topping up or bleeding is done as described by your installer. If the code stays, call the installer.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
Safety notes from the documentation
- Always switch off the power before remove and connect the component.[9]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 189 manufacturer document – copy from a distributor quote verified
H21 Abnormal water pressure
- [2] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
During operation of cooling and heating, the water pressure detected by the indoor water pressure sensor is used to determine water pressure error.
- [3] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
Continue for 180 seconds (but no judgment for 70 seconds after Water pump startup/restart).
- [4] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
Faulty water pump.
- [5] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
Water leak in system.
- [6] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
Faulty connector connection.
- [7] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
Faulty water pressure sensor.
- [8] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
Faulty indoor unit PCB (main).
- [9] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 194 manufacturer document – copy from a distributor quote verified
always switch off the power before remove and connect the component.