Panasonic · Heat pumps · Panasonic Aquarea Bi-bloc (split), generation L (R290)
H23Indoor refrigerant liquid temperature sensor abnormality
Name in the manufacturer's documentation (service manual): Indoor refrigerant liquid temperature sensor abnormality
[1]
In plain words (editorial)
The controller gets an implausible reading from the refrigerant liquid temperature sensor – usually a connector, the sensor itself or the PCB.
When to call a service technician: Ask the installer to check the sensor, its connector and wiring (power off first).
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Detection conditions (source text)
Possible causes (source text)
Safety notes from the documentation
- Always switch off the power before remove and connect the component.[7]
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 189 manufacturer document – copy from a distributor quote verified
H23 Indoor refrigerant liquid temperature sensor abnormality
- [2] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 196 manufacturer document – copy from a distributor quote verified
During startup and operation of cooling and heating, the temperatures detected by the outdoor refrigerant liquid temperature sensor are used to determine sensor error.
- [3] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 196 manufacturer document – copy from a distributor quote verified
Continue for 5 seconds.
- [4] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 196 manufacturer document – copy from a distributor quote verified
Faulty connector connection.
- [5] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 196 manufacturer document – copy from a distributor quote verified
Faulty sensor.
- [6] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 196 manufacturer document – copy from a distributor quote verified
Faulty indoor unit PCB (main).
- [7] Service Manual – WH-SDC0509L3E5 / L6E5 + WH-WDG05/07/09LE5 (R290) (PAPAMY2307068CE) , p. 196 manufacturer document – copy from a distributor quote verified
always switch off the power before remove and connect the component.