Samsung · Split air conditioners · Samsung WindFree AR50F / AR60F / AR70F (wall-mounted split, R32)
C554Gas shortage error
Name in the manufacturer's documentation (service manual): Gas shortage error
[1]
In plain words (editorial)
Refrigerant (gas) shortage. The service manual names a refrigerant shortage, a badly tightened service valve, pipe failures or leaks in the indoor evaporator or outdoor condenser, and – where several units were installed at once – wrongly connected pipes or communication wires.
When to call a service technician: Contact an authorised Samsung service technician.
✎ editorial – written from the cited sources, not a manufacturer statement. Status: draft.
For technicians
Possible causes (source text)
Steps given by the manufacturer (source text)
⚠ Work on refrigerant circuits, mains electricity and PV DC wiring is for qualified technicians only.
The Polish page has more detail (plain-language explanation, safe checks, guides): Read in Polish →
Sources
Every statement has a footnote to the document and PDF page. “Quote verified” means the quote was found automatically in the text of that page.
- [1] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 20 manufacturer document – copy from a distributor quote verified
GAS SHORTAGE ERROR
- [2] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
check whether communication wire
- [3] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
Service valve tightening status defect
- [4] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
Pipe failure
- [5] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
EVAP leakage
- [6] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
COND leakage
- [7] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
Shortage of refrigerant
- [8] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
Charge the refrigerant
- [9] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
Tighten Service valve
- [10] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
Check the pipe leakage (leakage of EVAP of
- [11] Samsung – Split-type Air Conditioner Service Manual (indoor AR50F/AR60F/AR70F…C1A…NEU, outdoor …XEU), „GEO WIND FREE EU RS9 25R” (RS9 25R (2025-10-01, wg nazwy pliku)) , p. 114 manufacturer document – copy from a distributor quote verified
Replace OUTDOOR PBA